Industrial hydraulic solutions · Built to keep your equipment running
Oil Guard
Oil-Stop Reservoir Cap Switch
A $159 switch that prevents a $10,000 problem.
Stop a leak before it stops your wallet — or the EPA.
Oil Guard replaces the standard 3/4″+ threaded vented oil fill cap on your hydraulic reservoir with an adjustable low-level float switch. Set the float to the minimum oil level your operation tolerates. If oil drops below that line — a hose lets go, a fitting weeps overnight, a cylinder seal fails — the float falls, the circuit opens, and your pump stops. The leak stops with it.
Oil Guard — drop-in replacement for a vented hydraulic reservoir fill cap
The math: one leak it stops pays for 50+ units
Replacement oil (30-gal reservoir)
$720
Run-dry pump damage (typical)
$1,500 – $4,000
EPA-reportable spill cleanup
$5,000 – $50,000+
Lost route / facility downtime
$500 – $5,000+
Total exposure per spill incident
$7,720 – $60,000+
Total exposure per spill incident
$159 / unit
The asymmetry is the point.
Your worst day without Oil Guard costs five figures and a call to the state environmental office. Your worst day with it costs a service call, a few gallons of oil, and ten minutes to reset.
How It Works
1
Unscrew
Remove your existing 3/4″+ threaded vented oil fill cap from the reservoir.
2
Thread In & Set
Install the Oil Guard in the same port. Slide the float collar to your minimum-acceptable oil level and tighten the bushing.
3
Wire It
Two leads — wire to a PLC digital input (programmed to stop the pump on open) OR in series with the motor-starter relay coil for direct shut-off. The pre-wired quick-disconnect lets you remove the cap to top off oil without re-terminating wires.
Two Ways to Wire It
Option A · PLC Input
Wire both leads to a 24 VDC or 120 VAC PLC digital input. Program the logic to:
Stop pump output on contact open
Trigger fault alarm / HMI message
Log timestamp for maintenance
Best for: new builds, smart compactors, fleet equipment with telemetry.
Option B · Motor-Starter Series
Wire the switch in series with the motor starter’s hold-in / coil circuit (up to 120 VAC). On low oil, the contact opens, the coil drops out, the pump motor stops. No controller required.
Best for: retrofits, legacy compactors, operations without a PLC.
Specifications
Voltage rating
Up to 120 VAC
Contact configuration
Normally-closed dry contact
Trigger
Opens on low-oil float drop
Mounting thread
3/4″ NPT min., larger on request
Bushing
Adjustable, set trigger height
Float rod
304 stainless steel
Cap function
Replaces existing vented fill cap
Coupling
IP-rated quick-disconnect
PLC compatibility
Any digital input, 24 VDC or 120 VAC
Direct control
Series with motor-starter coil
Ordering & Contact
$159
per unit, OEM qty 10 minimum
Ordering & Contact
Adjustable threaded bushing
Vented oil fill cap
304 SS float rod + float
Pre-wired leads w/ IP-rated coupling
Custom options:
Larger thread (1″, 1-1/4″, etc.)
Custom rod lengths for deep tanks
Dual-level (low + critical)
Lead time: ~2 weeks from PO
Ready to stop the next leak before it stops you?
Email us for OEM pricing, custom configurations, or a sample evaluation unit.