| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-1 | Nothing at all — no lights, no hum, no response | Main disconnect off or padlocked, tripped feeder breaker, blown line fuse, utility outage | Disconnect handle position. Whether other equipment on that panel has power. Whether someone locked it out and forgot to release it | Tier 1 | Both | Diagnose the feeder, replace fuses or the disconnect switch, repair damaged whip or conduit |
| E-2 | Control power is on but the start button does nothingOn a baler the same fault sits in the foot switch, key switch or chamber-door interlock. | Latched emergency stop, open door or chute interlock, blown control transformer fuse, failed pushbutton contact block, key switch off | Every E-stop station — buildings often have more than one and the second gets forgotten. Access door fully latched. Chute door closed. Key switch position | Tier 1 | Both | Replace pushbuttons, key switches, interlock switches, control transformer; repair control wiring |
| E-3 | Motor hums loudly but does not turn; overload trips in seconds›Full guide | Single-phasing — one leg lost at a fuse, breaker or starter contact. Seized pump. Locked rotor | Hum plus a fast trip is a classic lost-leg signature. Do not keep resetting the overload — each restart cooks the windings further | Tier 3 | Both | Verify all three legs under load, replace fuses or starter, repair or replace pump or motor |
| E-4 | Motor runs, ram never moves, no pressure builds | Reversed phase rotation after utility work, a panel change or a new starter — the motor is turning backwards | Any compactor that quits right after electrical work upstream should be checked for rotation first. It sounds completely normal and does nothing | Tier 3 | Both | Confirm rotation, swap two legs at the starter, verify pump pressure |
| E-5 | Overload trips repeatedly after several minutes of running | Overload set wrong, heat in a closed enclosure, motor bearing drag, hydraulics running against the relief, low supply voltage | How long it runs before tripping. An instant trip is electrical; a delayed trip is usually load or heat | Tier 2 | Both | Correct overload sizing, motor bearing service or replacement, fix the hydraulic cause of high back pressure |
| E-6 | Breaker or fuse blows the instant the motor starts | Shorted motor winding, damaged supply conductor, water in a junction box or motor peckerhead, welded contactor | Nothing here is a site check. A repeatedly blown breaker is a fault current path, not a nuisance | Tier 3 | Both | Megger the motor, repair or replace conductors, replace motor or starter |
| E-7 | Ground fault trips, often in wet weather | Moisture in the motor or junction box, chafed conductor in flex conduit, insulation breakdown from vibration | Whether the trip tracks with rain, washdown or cold-weather condensation | Tier 3 | Compactor | Locate and repair the fault, reseal enclosures, install proper drip loops and drains |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-8 | Ram runs only while the button is heldOn a foot-switch vertical baler this is normal, designed behaviour — not a fault. Only a machine that used to latch and now does not has a problem. | Sequence is not latching — failed holding contact, failed extend limit or proximity switch, seal-in relay, PLC input not seeing the start | On a relay unit this is usually one relay or one switch. On a PLC unit the input LED tells the story immediately | Tier 3 | Compactor | Replace the relay, limit switch or proximity sensor, repair the input wiring, correct the PLC input |
| E-9 | Ram cycles continuously and will not stop at end of stroke | Extend limit or proximity sensor never made — bent actuator arm, sensor knocked out of position, failed sensor, broken target | Look for a bent or debris-packed limit switch actuator with the machine locked out. This is the most common sensor failure on a compactor | Tier 2 | Both | Replace and re-set limit switches and proximity sensors, repair actuator arms and mounting brackets |
| E-10 | Unit stops mid-stroke and will not resume | Sequence timer expired on a jam, overload trip, safety circuit opened mid-cycle, PLC fault, pressure not reaching the switch, loading door opened | Whether the ram stopped against material (a jam) or in free travel (a control fault). Also confirm the loading door is fully closed and, on a self-contained unit, that the quick-disconnect hoses are properly coupled | Tier 2 | Both | Clear the fault, correct the jam cause, repair the timer, sensor or PLC logic |
| E-11 | “Container Full” light on with a visibly empty container›Full guide | Pressure switch set too low or failed closed, full-signal latch relay stuck, PLC counter not cleared after the last pull, failed reset button | Whether the light clears after a proper reset. If it returns on the first cycle, the pressure switch is the prime suspect | Tier 2 | Compactor | Test and re-set or replace the pressure switch, repair the latch relay or PLC logic, correct the reset circuit |
| E-12 | Container is packed solid but no “Full” indication | Failed pressure switch, burned-out indicator lamp, broken signal wire, disconnected monitoring service, PLC output failure | The lamp itself. Indicator bulbs are the cheapest possible failure and get overlooked for months while the container gets overpacked | Tier 1 | Compactor | Replace pressure switch or lamp, repair signal wiring, restore fullness-monitoring integration |
| E-13 | Chute or access door will not unlock after the cycle | Interlock solenoid failure, misaligned interlock switch, unlock timer not timing out, control relay failure, door frame racked out of square | Whether the door is mechanically binding or electrically not releasing. Push and listen for the solenoid | Tier 2 | Compactor | Replace interlock switch or solenoid, realign the door and frame, repair the timer circuit |
| E-14 | Bagging unit will not restart after a bag change | Bag-change interlock not satisfied, carousel index sensor not made, door switch out of adjustment, reset not performed | The interlock and index sensor positions — these get bumped on every bag change | Tier 2 | Compactor | Replace and align interlock and index sensors, repair door hardware |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-15 | HMI screen blank or frozen, machine dead | 24VDC power supply failure, blown DC-side fuse, HMI backlight failure, corrupted screen program | Whether the PLC run LED is still lit with the screen dark — that separates a display failure from a controller failure | Tier 3 | Compactor | Replace the DC power supply or HMI, restore the program, repair DC distribution |
| E-16 | PLC fault light on, error code on the screen | I/O module fault, watchdog timeout, low controller battery, program corruption, a field device short pulling down an output | The code itself and which I/O LEDs are lit. Photograph the screen before clearing anything — the code is often the fastest diagnosis we get | Tier 2 | Compactor | Fault diagnosis, module replacement, program restore, field device repair |
| E-17 | Erratic behavior in cold or wet weather | Condensation in the enclosure, failed enclosure heater, corroded terminal blocks, water tracking in through a bad conduit seal | Whether the fault correlates with weather. Look for rust streaks and green corrosion at the bottom of the cabinet | Tier 2 | Compactor | Reseal the enclosure, replace heater and thermostat, replace corroded terminals and wiring |
| E-18 | Relay-logic unit works intermittently — fine for days, then notMore relevant on balers than compactors — vertical balers are relay-logic machines. | Pitted relay or contactor contacts, terminal screws loosened by years of vibration, cracked solder joint on a timer, tired relay coils | Vibration loosens terminals on every compactor eventually. Intermittent is nearly always a connection | Tier 3 | Both | Retorque and repair terminations, replace relays, contactors and timers — or upgrade the panel to PLC control |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-1 | Nothing at all — no lights, no hum, no response | Main disconnect off or padlocked, tripped feeder breaker, blown line fuse, utility outage | Disconnect handle position. Whether other equipment on that panel has power. Whether someone locked it out and forgot to release it | Tier 1 | Both | Diagnose the feeder, replace fuses or the disconnect switch, repair damaged whip or conduit |
| E-2 | Control power is on but the start button does nothingOn a baler the same fault sits in the foot switch, key switch or chamber-door interlock. | Latched emergency stop, open door or chute interlock, blown control transformer fuse, failed pushbutton contact block, key switch off | Every E-stop station — buildings often have more than one and the second gets forgotten. Access door fully latched. Chute door closed. Key switch position | Tier 1 | Both | Replace pushbuttons, key switches, interlock switches, control transformer; repair control wiring |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-12 | Container is packed solid but no “Full” indication | Failed pressure switch, burned-out indicator lamp, broken signal wire, disconnected monitoring service, PLC output failure | The lamp itself. Indicator bulbs are the cheapest possible failure and get overlooked for months while the container gets overpacked | Tier 1 | Compactor | Replace pressure switch or lamp, repair signal wiring, restore fullness-monitoring integration |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-5 | Overload trips repeatedly after several minutes of running | Overload set wrong, heat in a closed enclosure, motor bearing drag, hydraulics running against the relief, low supply voltage | How long it runs before tripping. An instant trip is electrical; a delayed trip is usually load or heat | Tier 2 | Both | Correct overload sizing, motor bearing service or replacement, fix the hydraulic cause of high back pressure |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-9 | Ram cycles continuously and will not stop at end of stroke | Extend limit or proximity sensor never made — bent actuator arm, sensor knocked out of position, failed sensor, broken target | Look for a bent or debris-packed limit switch actuator with the machine locked out. This is the most common sensor failure on a compactor | Tier 2 | Both | Replace and re-set limit switches and proximity sensors, repair actuator arms and mounting brackets |
| E-10 | Unit stops mid-stroke and will not resume | Sequence timer expired on a jam, overload trip, safety circuit opened mid-cycle, PLC fault, pressure not reaching the switch, loading door opened | Whether the ram stopped against material (a jam) or in free travel (a control fault). Also confirm the loading door is fully closed and, on a self-contained unit, that the quick-disconnect hoses are properly coupled | Tier 2 | Both | Clear the fault, correct the jam cause, repair the timer, sensor or PLC logic |
| E-11 | “Container Full” light on with a visibly empty container›Full guide | Pressure switch set too low or failed closed, full-signal latch relay stuck, PLC counter not cleared after the last pull, failed reset button | Whether the light clears after a proper reset. If it returns on the first cycle, the pressure switch is the prime suspect | Tier 2 | Compactor | Test and re-set or replace the pressure switch, repair the latch relay or PLC logic, correct the reset circuit |
| E-13 | Chute or access door will not unlock after the cycle | Interlock solenoid failure, misaligned interlock switch, unlock timer not timing out, control relay failure, door frame racked out of square | Whether the door is mechanically binding or electrically not releasing. Push and listen for the solenoid | Tier 2 | Compactor | Replace interlock switch or solenoid, realign the door and frame, repair the timer circuit |
| E-14 | Bagging unit will not restart after a bag change | Bag-change interlock not satisfied, carousel index sensor not made, door switch out of adjustment, reset not performed | The interlock and index sensor positions — these get bumped on every bag change | Tier 2 | Compactor | Replace and align interlock and index sensors, repair door hardware |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-16 | PLC fault light on, error code on the screen | I/O module fault, watchdog timeout, low controller battery, program corruption, a field device short pulling down an output | The code itself and which I/O LEDs are lit. Photograph the screen before clearing anything — the code is often the fastest diagnosis we get | Tier 2 | Compactor | Fault diagnosis, module replacement, program restore, field device repair |
| E-17 | Erratic behavior in cold or wet weather | Condensation in the enclosure, failed enclosure heater, corroded terminal blocks, water tracking in through a bad conduit seal | Whether the fault correlates with weather. Look for rust streaks and green corrosion at the bottom of the cabinet | Tier 2 | Compactor | Reseal the enclosure, replace heater and thermostat, replace corroded terminals and wiring |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-3 | Motor hums loudly but does not turn; overload trips in seconds›Full guide | Single-phasing — one leg lost at a fuse, breaker or starter contact. Seized pump. Locked rotor | Hum plus a fast trip is a classic lost-leg signature. Do not keep resetting the overload — each restart cooks the windings further | Tier 3 | Both | Verify all three legs under load, replace fuses or starter, repair or replace pump or motor |
| E-4 | Motor runs, ram never moves, no pressure builds | Reversed phase rotation after utility work, a panel change or a new starter — the motor is turning backwards | Any compactor that quits right after electrical work upstream should be checked for rotation first. It sounds completely normal and does nothing | Tier 3 | Both | Confirm rotation, swap two legs at the starter, verify pump pressure |
| E-6 | Breaker or fuse blows the instant the motor starts | Shorted motor winding, damaged supply conductor, water in a junction box or motor peckerhead, welded contactor | Nothing here is a site check. A repeatedly blown breaker is a fault current path, not a nuisance | Tier 3 | Both | Megger the motor, repair or replace conductors, replace motor or starter |
| E-7 | Ground fault trips, often in wet weather | Moisture in the motor or junction box, chafed conductor in flex conduit, insulation breakdown from vibration | Whether the trip tracks with rain, washdown or cold-weather condensation | Tier 3 | Compactor | Locate and repair the fault, reseal enclosures, install proper drip loops and drains |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-8 | Ram runs only while the button is heldOn a foot-switch vertical baler this is normal, designed behaviour — not a fault. Only a machine that used to latch and now does not has a problem. | Sequence is not latching — failed holding contact, failed extend limit or proximity switch, seal-in relay, PLC input not seeing the start | On a relay unit this is usually one relay or one switch. On a PLC unit the input LED tells the story immediately | Tier 3 | Compactor | Replace the relay, limit switch or proximity sensor, repair the input wiring, correct the PLC input |
| # | Symptom | Likely causes | What to check | Who Checks | Applies to | What we do |
|---|---|---|---|---|---|---|
| E-15 | HMI screen blank or frozen, machine dead | 24VDC power supply failure, blown DC-side fuse, HMI backlight failure, corrupted screen program | Whether the PLC run LED is still lit with the screen dark — that separates a display failure from a controller failure | Tier 3 | Compactor | Replace the DC power supply or HMI, restore the program, repair DC distribution |
| E-18 | Relay-logic unit works intermittently — fine for days, then notMore relevant on balers than compactors — vertical balers are relay-logic machines. | Pitted relay or contactor contacts, terminal screws loosened by years of vibration, cracked solder joint on a timer, tired relay coils | Vibration loosens terminals on every compactor eventually. Intermittent is nearly always a connection | Tier 3 | Both | Retorque and repair terminations, replace relays, contactors and timers — or upgrade the panel to PLC control |
Scroll sideways for every column. On a phone each symptom becomes its own card.
Every symptom on this page carries one of three labels. The label tells you where your own checking safely stops. This is not a liability disclaimer — it is the honest answer to a question facility managers ask us constantly: how much of this can my own people handle?
Tier 1 · Site Check
Tier 2 · Qualified Maintenance
Tier 3 · Service Technician
480 volts, three phase. An arc flash inside a compactor control cabinet is a burn injury, not a shock. The control components inside that cabinet run on 120V or 24VDC — which is exactly why people open the door and get hurt. The 480V line side is right there beside them.
Stored hydraulic energy. A compactor parked with the ram out has a loaded cylinder and pressurized lines even with the motor off and locked out. Cracking a fitting “to see if there’s pressure still in it” is how people get injection injuries. Pressure is relieved deliberately and confirmed at the gauge before anything is opened.
The safety framework behind these tiers comes from ANSI Z245.2 (Stationary Compactors — Safety Requirements for Installation, Maintenance and Operation), OSHA 29 CFR 1910.147 (Control of Hazardous Energy), and NFPA 70E (Electrical Safety in the Workplace). Welding and cutting on a building in Massachusetts falls under 527 CMR 1.00, Chapter 41.